Here is a cheat sheet we use to identify where and what each connection on the DNS80 spin boards are connected to. This specific unit has connections for SC2, SCN5, SCN3, SN4, SCN6, SCN8, SCN10, SCN12 and SCN13 on the EESC-0012 spin board.
Connector | Board | Description | Where does it go ? |
SCN2 | EESC-0012 Spin Board A | Board A Input 1-30, Output 1-8, 24V, 12V, GND | External Alarm IFC |
SCN3 | EESC-0012 Spin Board A | Inputs 1-38. Outputs 1-7, but there are really 32 serparate outputs | Mech I/O to Spin mechanical section IFC Board |
SCN4 | EESC-0012 Spin Board A | Inputs 1-8. 4 Inputs for M3 control. 4 outputs for M3. | SCN4A Cup Section |
SCN5 | EESC-0012 Spin Board B | Inputs 1-32, Outputs 1-24, 24V, 12V, GND | Spin Chemical IFC |
SCN6 | EESC-0012 Spin Board B | Only has one input and output | AC power supply interface |
SCN8 | EESC-0012 Spin Board B | Inputs 1-12, Outputs 1-8 | Not Connected |
SCN10 | EESC-0012 Spin Board C | TXA, RXA, RS232 | AC power supply interface |
SCN11 | No Connector | ||
SCN12 | EESC-0012 Spin Board C | BUS1+ , BUS1- | RS485 to Chemical Temperature Controller, AKA “Thermostatic Control Unit” |
SCN13 | EESC-0012 Spin Board C | BUS2+ , BUS2- TXB2, RXB2 | Not Connected |