Partname Partcategory Description Oem Model Datefield Picture1 Price
CERB-1016 2-VC-15254-1 Slave Board Transport Station Controller DNS 60A
CESB-2011 2-VC-19075 Slave Board Spin control board. Station Controller DNS
CEYD-0015 2-VC-13743 Power Supply 60A Power Controller DNS 60A
EEMP-0021X3 LCD Main Display Panel DNS 60A
CEBB-1011 Slave Board Station Controller Board BAKE DNS 60A
CERD-0111 Axis Controller Old style axis controller for robot DNS 60A
AU3585N222 CESA-0014 Servo Amp Old servo for DNS X”A” style DNS 60A

AU3585N222 CESA-0014, CERD-0111, CEBB-1011, EEMP-0021X3, CESB-2011 2-VC-19075, CERB-1016 2-VC-15254-1, AU3585N222 CESA-0014 Servo Amp, CEBB-1011 Station Controller Board BAKE, CERB-1016 2-VC-15254-1 Transport Station Controller, CESB-2011 2-VC-19075 Spin control board. Station Controller, CEYD-0015 2-VC-13743-GSRPR, EEMP-0021X3 LCD DISPLAY

Origin Return for Dainippon Screen DNS 80B Coat Develop Track


Take a look at these videos of robots, computers and other track pieces in action..

A way to communicate failure symptom for DNS track is to run the Origin Return / Lot Clear operation after a boot up. We collect videos of this process for different pieces during the origin return. Take a look and if you have any interesting DNS behavior that could help other technicians isolate track failures please email us at info@comvolt.com and we will post it for everybody to see.

Look at this spin cup during an origin return..Mostly just the nozzle arms move.


How about origin return of the transport robot?

Depending on where the origin return fails, it can point you which controller is failing. Typical error codes are:

1-03-0247, 1-03-0201, 1-03-0107, 1-01-0112, 1-02-0120, 1-03-1010, 1-03-0210, 1-03-0252, 1-03-0253, 1-01-0221 , 1-03-0242, 1-03-0254, 1-01-0310, 1-03-0258, 1-03-0255, 1-02-0470, 1-00-0023, 1-03-2001, 1-03-2101, 1-05-0015, 1-01-0210, 1-02-410, 01-02-0121, 1-03-0254, 1-03-0220, 1-01-0210, 1-06-0206, 1-00-0025, 1-03-0251

2-39-45431, 2-39-51930 2-39-61074 UT3-F1AE, 2-39-51930 2-39-61074 UT3-F1AE /DSS1-A, 2-39-51930 2-39-61074 UT3-X3AE / DSS4-A, 2-VC-15485 EEKA-0011 2-VC-23936 MR-J10-S07, 2-VC-16217-1EEBH-0021, 2-VC-19090 EERC-0012, 2-VC-19090 EERC-0013, 80A, 80B, 80B Scrubber AU6351N60 2-39-57597, CEDB-1013 2-VC-15252, CEMP-0016 EEMP-0021X3, CERB-1016 2-VC-15254-1, CESA-804, CESB-2011 2-VC-19075, CESB-2012, CESP-0002 2-VC-42102, CESP-0017, CESP-001A F-VC-40833, CESP-002, CEYD-0015 2-VC-13743, 2-VC-28124 GEIA-001, EEBH-0011, EEDC-0011 2-VC-19089, EEJA-001A, EESA-001 AU3575N223, EESA-001 AU3575N233 2-39-48133 , EESA-001A1 AU6356N20 EESA-001 2-39-53462, EESC-0012 2-VC-19115 Spin Slave, EEUC-0013, EEUD-0013, EEUE-001, EEUE-001B, EEUE-001X1, EEW, EEYC-0011 2-VC-20626, GEIC-002 BP-0015C, GEPH-001X3, GESA-001 AU6354N40 2-VC-27621Hamamatsu,IDI, IDI/Cybor, INR-244-216, INR-244-402 2-39-45751, INR-497-001B, INR-497-P2393 Motherboard, Motor, Motor Controller, OMRON, Photolithograpy, PiBoc, Power Supply, Robot Controller, Robots Servo Amp, Servo Driver, Slave Board, Slave Board , Stage Driver, Super Vexta UDX5107, ESP-002A2, Touchscreen VGA, Vexta,

Another Sample of Failed Semiconductor Fab Electonics and Happy Endings


GetSparesCESP-002
DNS
maintenance panel with SCN5
80B
DNS
Photolithograpy
05/02/2019Repaired/shipped
GetSparesTESP-002A2
DNS
maintenance panel with SCN5
80B
DNS
Photolithograpy
05/02/2019Custom solution/shipped
GetSparesPCS4900/DELL
Therma-Wave
Single board computer
Opti-probe 2600-2690 3260-3290
Thermawave/KLA
Inspection
05/02/2019Repaired/shipped
GetSparesCESB-1011
DNS
Spin control board. Station Controller DNS
80A
DNS
Photolithograpy
04/17/2019Repaired/shipped
GetSpares90-2590 16495-01B 16495-01
Gasonics
Branson/IPC, I/O interface
L3510
Novellus/Gasonics
RIE/Plasma
04/12/2019Repaired/shipped
GetSpares90-2590 16495-01B 16495-01
Gasonics
Branson/IPC, I/O interface
L3510
Novellus/Gasonics
RIE/Plasma
04/12/2019Custom solution/shipped
GetSparesEESA-001A1 AU6356N20 EESA-001 2-39-53462
DNS
servo amp
80B
DNS
Photolithograpy
04/11/2019Repaired/shipped
GetSparesEESA-001A1 AU6356N20 EESA-001 2-39-53462
DNS
servo amp
80B
DNS
Photolithograpy
04/11/2019Custom solution/shipped
GetSparesEESA-001A1 AU6356N20 EESA-001 2-39-53462
DNS
servo amp
80B
DNS
Photolithograpy
04/01/2019Repaired/shipped
GetSparesCESP-0002 2-VC-42102
DNS
maintenance panel with SCN5
80B
DNS
Photolithograpy
03/28/2019Repaired/shipped
GetSparesCESP-0002 2-VC-42102
DNS
maintenance panel with SCN5
80B
DNS
Photolithograpy
03/28/2019Custom solution/shipped
GetSpares36-0201 54-0219
Prometrix
H2 Interface PCB for UV1050/UV1250
UV1050
Tencor/KLA
Inspection
12/14/2018Repaired/shipped
GetSpares36-0294
Prometrix
Turret Servo Driver 54-0294
UV1250-UV1280
Tencor/KLA
Inspection
12/12/2018Repaired/shipped
GetSpares36-0287 54-0287 RevAB
Prometrix
PCB Stage Driver F2 Rev. F
UV1250-UV1280
Tencor/KLA
Inspection
12/12/2018Custom solution/shipped
GetSpares36-0287 54-0287 RevAB
Prometrix
PCB Stage Driver F2 Rev. F
UV1250-UV1280
Tencor/KLA
Inspection
12/12/2018Repaired/shipped
GetSpares36-0294
Prometrix
Turret Servo Driver 54-0294
UV1250-UV1280
Tencor/KLA
Inspection
12/12/2018Repaired/shipped
GetSparesVLT 2800
DanFoss
drive water pump in chillers
ASML chiller
Neslab
Chiller
10/05/2018Repaired/shipped
GetSparesEST0220C05WNXE1
SMC
Smart Terminal
INR-497-001B
SMC
Water Chiller
09/10/2018Repaired/shipped
GetSparesPS500 2-39-55593
DNS
Battery backed power supply
80B
DNS
Photolithograpy
07/15/2018Repaired/shipped
GetSparesEEBH-0011X1
DNS
heater control bake unit
80B
DNS
Photolithograpy
06/28/2018Repaired/shipped
GetSpares780-14091-000
KLA
CD Sem Column Aligner
8100 8100XP 8100XPR 8250 8300 8450
KLA
SEM
06/05/2018Custom solution/shipped
GetSparesVLT 2800
DanFoss
drive water pump in chillers
ASML chiller
Neslab
Chiller
05/23/2018Custom solution/shipped
GetSpares36-0004 (Alternate 54-0005 or 54-0389)
Prometrix
Current Source PCB
RS55
Prometrix/KLA
Wafer Resistivity
02/04/2016Repaired/shipped

DNS 80B Track – Removing Supply from EEYC-0011 EEYC-0111 2-VC-20626 2-VC-20627

This post shows how to remove the power supply from the side of the station controller for DNS 80B coater/developer tracks. There is no need to remove the whole card cage if you are sending in a repair. It would be too bulky. The part here can go by a variety of names such as EEYC-0011, EEYC-0111, 2-VC-20626 and 2-VC-20627. Remember contact www.GetSpares.com for this or any other semiconductor tool parts that you need. Here you go…

This is a rare case where we recommend that the customer open a part to send a controller by itself

INR-244-402 aka 2-39-45751 Chemical Temperature Controller for DNS 80B

The Chemical Temperature Control unit (part number INR-244-402 aka 2-39-45751) for DNS 80B photolithography track is a known failure point.  Symptoms include communication errors, error code “00”, and failure to meet temperature set point.

GetSpares.com has discovered the electronic repair solutions for restoring these units to operational status.  Additionally, GetSpares.com maintains functional DNS tracks on the warehouse floor, providing a conclusive test environment for any DNS parts.

Contact GetSpares.com today for your repair or replacement needs!

Front View: INR-244-402 aka 2-39-45751 Chemical Temperature Control Unit for DNS 80B

Front View: INR-244-402 aka 2-39-45751 Chemical Temperature Control Unit for DNS 80B

Rear View: INR-244-402 aka 2-39-45751 Chemical Temperature Control Unit for DNS 80B

Rear View: INR-244-402 aka 2-39-45751 Chemical Temperature Control Unit for DNS 80B

GEIA-001 (aka 2-VC-28124) 6-axis Motor Driver for DNS SK200 Interface-B Unit

The 6-axis Motor Driver, part numbers GEIA-001 or 2-VC-28124, drives the handler robots EV1 and EV2 in the Interface-B (IF-B) unit of DNS SK200 coater track.  Faulty handler operation in the IF-B has been traced back to failed electronics in the 6-axis Motor Driver.

GetSpares maintains functional DNS tracks on their floor as well as the engineering capability to repair and test associated parts and electronics.

If you are experiencing handler motor drive problems in your DNS equipment, contact GetSpares.com today for the right solution!

GEIA-001 (aka 2-VC-28124) 6-axis Motor Driver for DNS SK200

GEIA-001 (aka 2-VC-28124) 6-axis Motor Driver for DNS SK200

GEPH-001/GEPH-001X3 AC Box Power Supply for DNS SK200 Coater Track

Power failures in DNS SK200 coater track have been traced back to failed electronics in the AC Power Supply Box – part number GEPH-001/GEPH-001X3.

GetSpares maintains functional DNS tracks on their floor as well as the engineering capability to repair and test associated parts and electronics.

 

If you are experiencing general power failures (or even a “dead” track) in your DNS equipment, contact GetSpares.com today for the right solution!

GEPH_001X3 AC Power Supply Box DNS SK200

GEPH_001X3 AC Power Supply Box DNS SK200

Driver Motor Box Servo Amplifier PK CESA-804 for DNS 80A Track

Communication and Rev errors in the spin units of DNS 80A tracks have been traced back to faulty electronics in the Servo Amplifier Pack – part number CESA-804.

GetSpares maintains functional DNS tracks on their floor as well as the engineering capability to repair and test associated parts and electronics.

Example alarm that has been resolved:

-CODE 1-03-0247 [station 1 – unit 3 (spin) – code 0247]:                                              Servo Controller Communication Error 

If you are experiencing any communication or “rev” (RPM) errors in the spin units of your DNS equipment, contact GetSpares.com today for the right solution!

CESA-804 Servo Amp Pack for DNS 80A

CESA-804 Servo Amp Pack for DNS 80A

Indexer Control Board CEDB-1013 aka 2-VC-15252 for DNS 80A Track

A number of flow errors at the Indexer module of a DNS 80A track have been traced back to failures in the Indexer Control Board – part numbers CEDB-1013,  2-VC-15252 or 2-VC-1524-1. 2-VC-15254-1  GetSpares maintains functional DNS tracks on their floor as well as the engineering capability to repair and test associated parts and electronics.

Example alarms that have been resolved include:

CODE 1-01-0210 [station 1 – unit 1 (indexer) – code 0210]:                                        Faulty Indexer Horizontal Axis Operation

CODE 1-01-0220 [station 1 – unit 1 (indexer) – code 0220]:                                         Faulty Indexer Horizontal Axis Origin Return

If you are experiencing this or similar flow alarms on your DNS equipment, contact GetSpares.com today for the right solution!

Indexer Control Board CEDB-1013 for DNS 80A

Indexer Control Board CEDB-1013 for DNS 80A