This is a story of two Cluster Misc Controller from a Novellus / Gasonics PEP 3510. There are other Cluster-Misc boxes, but the ones we see frequently from
are the 95-3155 and the 95-0538. They are identical and work exactly the same…WRONG!! Check your PEP-3510 to make sure which one you have. The 95-3155 has a J6 connector called AC Power/PWR Detect. The 95-0538 does not. These two boxes are almost identical except if used in place of each other, there can be status errors reported in the tool and it can cause wafers to halt or not run at all.
Common error codes due to failure for these boxes are:
“Door won’t close in a reasonable amount of time”
“CC-0520 Cluster Misc-Invalid status data in Left Cooler”
“CC-0810 Cluster Misc-Invalid status data in Right Cassette”
“CC-0710 Cluster Misc-Invalid status data in Left Cassette”
“CC-0620 Cluster Misc-Invalid status data in Right Cooler”
“CC-0616 Cluster Misc-Service error in Right Cooler”
As always, if you think your PEP 3510 or any other Semiconductor tool needs parts, contact