If you are experiencing “Bake Temperature Error”, “Bake Temperature Incomplete” or other general failures with the bake units in a DNS 80A or 80B tracks, the Heater Controllers EEBH-6011 or EEBH-0011 have likely failed. Not to fear, GetSpares.com maintains DNS tracks and parts. These parts are available for sale when in stock, but can also be repaired if shipped to the GetSpares facility. If you see a error screens as pictured below, contact GetSpares today!
Tag Archives: bake unit
2-39-45431 Thermostatic Unit FRD-4, Cool Plate Controller for DNS 80B
The FRD-4 Thermostatic Unit serves as the controller for cool plates in the DNS 80B track. This unit is known to fail and can cause communication errors in the bake/cool process.
A good way to quickly check whether or not the FRD-4 communication circuit is functional is to check voltage on one of the output cables to cool plate units. The output cables connect to the right-most ports on the FRD-4. Each of them has a red wire and black wire that carry 5V DC power. Backprobe one of these connectors while it is connected to a live FRD-4 to verify the 5V power. If there is no voltage, the communication logic on-board the FRD-4 has suffered critical failure. Contact GetSpares.com for replacement or repair solutions.