INR-244-402 aka 2-39-45751 Chemical Temperature Controller for DNS 80B

The Chemical Temperature Control unit (part number INR-244-402 aka 2-39-45751) for DNS 80B photolithography track is a known failure point.  Symptoms include communication errors, error code “00”, and failure to meet temperature set point.

GetSpares.com has discovered the electronic repair solutions for restoring these units to operational status.  Additionally, GetSpares.com maintains functional DNS tracks on the warehouse floor, providing a conclusive test environment for any DNS parts.

Contact GetSpares.com today for your repair or replacement needs!

Front View: INR-244-402 aka 2-39-45751 Chemical Temperature Control Unit for DNS 80B

Front View: INR-244-402 aka 2-39-45751 Chemical Temperature Control Unit for DNS 80B

Rear View: INR-244-402 aka 2-39-45751 Chemical Temperature Control Unit for DNS 80B

Rear View: INR-244-402 aka 2-39-45751 Chemical Temperature Control Unit for DNS 80B

Driver Motor Box Servo Amplifier PK CESA-804 for DNS 80A Track

Communication and Rev errors in the spin units of DNS 80A tracks have been traced back to faulty electronics in the Servo Amplifier Pack – part number CESA-804.

GetSpares maintains functional DNS tracks on their floor as well as the engineering capability to repair and test associated parts and electronics.

Example alarm that has been resolved:

-CODE 1-03-0247 [station 1 – unit 3 (spin) – code 0247]:                                              Servo Controller Communication Error 

If you are experiencing any communication or “rev” (RPM) errors in the spin units of your DNS equipment, contact GetSpares.com today for the right solution!

CESA-804 Servo Amp Pack for DNS 80A

CESA-804 Servo Amp Pack for DNS 80A

2-39-45431 Thermostatic Unit FRD-4, Cool Plate Controller for DNS 80B

The FRD-4 Thermostatic Unit serves as the controller for cool plates in the DNS 80B track.  This unit is known to fail and can cause communication errors in the bake/cool process.

Front view of FRD-4 for DNS 80B

Front view of FRD-4 for DNS 80B

Cool Plate Controller Communication Error in DNS 80B caused by faulty FRD-4

Cool Plate Controller Communication Error in DNS 80B caused by faulty FRD-4

Front view of FRD-4 installed in DNS 80B.

Front view of FRD-4 installed in DNS 80B. Check communication 5V power at the output connectors.

 

 

 

 

 

 

 

A good way to quickly check whether or not the FRD-4 communication circuit is functional is to check voltage on one of the output cables to cool plate units.  The output cables connect to the right-most ports on the FRD-4. Each of them has a red wire and black wire that carry 5V DC power.  Backprobe one of these connectors while it is connected to a live FRD-4 to verify the 5V power.  If there is no voltage, the communication logic on-board the FRD-4 has suffered critical failure.  Contact GetSpares.com for replacement or repair solutions.