Other relevant and available parts are 2TP-2B575, INR-244-244T-670 and INR-244-253-6400 Operator Panel / Keypad -C3 -D9 . There are parts inside cabinet INR-244-211C-43.
If you isolate the problem to this, and need a replacement or repair contact GetSpares. Where they have a fully functional track running and ready to test and supply parts for you.
Error codes for SMC unit
E000 ROM check error. ROM check error at power supply.
E001 RAM check error. RAM checkerror at power supply.
E002 Back up data error. EEROM data is lost.
E100 Alarm at low voltage in power supply of thermo-modules . Occurs in case of over current.
E200 High temperature alarm. Occurs when the input value of control sensor exceeds 60C degrees.
E300 Low temperature alarm. Occurs When the input value of control sensor falls below 0 C.
E400 Thermostat alarm. Occurs when the contact point of a thermostat is open.
E500 Temp. control impossible. This alarm Works if termperature does not change properly (the range varies 0.1~0.9°C) when 100% output is continued for certain period of time (varies 1~60 min.)
E600 Flow switch alarm. Occurs when flow switch is ON.
E700 Alarm of control sensor broken wire. Occurs if broken disconnected.
E800 Pump abnormality alarm. Pump has something wrong.
E810 Water leakage abnormality alarm. water leakage sensor detects abnormality.
E820 Fan alarm. Cooling fan for each switching power supply stops.
E840 Level abnormality alarm. Level sensor detects abnormality.