TEL Tokyo Electron Clean Track – INR-244-216B SMC Thermo-Con Failure

Have a INR-244-216B that failed?  Common symptoms are E800 and E820 codes on the front panel.  Fan not spinning or LED not illuminated?  Contact GetSpares.com.  There is a fully functional track with its main purpose to test your parts or supply its parts for you in case of an emergency.  Below is a list of  of error codes that go along with the the SMC Thermo-Con on a Tel Clean Track.  E800 or E820 are the common failures for this INR-244-216 box. Note that, the track can run sometimes without error even if the the SMC Thermo-Con unit does have problems.

INR-244-211C-43 with INR-244-216

Other relevant and available parts are 2TP-2B575, INR-244-244T-670 and INR-244-253-6400  Operator Panel / Keypad -C3 -D9 .  There are parts inside cabinet INR-244-211C-43.

If you isolate the problem to this, and need a replacement or repair contact GetSpares.  Where they have a fully functional track running and ready to test and supply parts for you.

Error codes for SMC unit

 

E000 ROM check error. ROM check error at power supply.
E001 RAM check error. RAM checkerror at power supply.
E002 Back up data error. EEROM data is lost.
E100 Alarm at low voltage in power supply of thermo-modules . Occurs in case of over current.
E200 High temperature alarm. Occurs when the input value of control sensor exceeds 60C degrees.
E300 Low temperature alarm. Occurs When the input value of control sensor falls below 0 C.
E400 Thermostat alarm. Occurs when the contact point of a thermostat is open.
E500 Temp. control impossible. This alarm Works if termperature does not change properly (the range varies 0.1~0.9°C) when 100% output is continued for certain period of time (varies 1~60 min.)
E600 Flow switch alarm. Occurs when flow switch is ON.
E700 Alarm of control sensor broken wire. Occurs if broken disconnected.
E800 Pump abnormality alarm. Pump has something wrong.
E810 Water leakage abnormality alarm. water leakage sensor detects abnormality.
E820 Fan alarm. Cooling fan for each switching power supply stops.
E840 Level abnormality alarm. Level sensor detects abnormality.

Hamamatsu L6001-01, L6599-01, L6299-12 Fragile!

Before sending your Hamamatsu lamp house to GetSpares.com. Although, most arrive in great, re-buildable condition, great care must be taken so that the sensitive elliptical (also known as parabolic or ellipsoidal) mirror is not destroyed while in shipping.  This applies to all Hamamatsu light sources with these spherical reflectors such as L6001-01, L6599-01 and L6299-12.

Cracked Hamamatsu Mirror. So Sad!

Cracked Hamamatsu Mirror. So Sad!

Some guidelines for shipping Hamamatsu Lamp Houses:

  • Pack one per box for obvious reasons, you don’t want problems from lost or stolen packages to be magnified.  Replacement of these boxes is approximately $20,000 from the manufacturer and is not easy.
  • Use lots of protective packing.   Assume the box will be abused.
  • If the alignment posts on the mirror are already cracked or “thinned” from years of use, call GetSpares.com.  There are special instructions because standard shipping will very likely cause the remaining posts to crack and wreak havoc.
  • Remove bulb from unit.

The vast majority of units arrive in good shape, but we wanted to warn customers that care must be taken.  In case your curious, this particular Hamamatsu was refurbished  (extra mirror was expensive !) and is shining bright and exposing edge beads daily.

Dainippon Screen -80B Schematics Lists

List of schematics for DNS 80B tracks.    Here is a list of schematics for control schematics.

D-SPIN 80B ELECTRICAL CIRCUIT DIAGRAM LIST
ELECTRICAL CIRCUIT DIAGRAM LIST
HIGH PRESSURE GENERATION UNIT
JEHP-005
co2 BUBBLING CONTROLLER
SECO-1053
cog BUBBLING UNIT
SECV-104
MAINTENANCE PANEL [ SPIN UNIT 1
CESP-0015
STEPDOWN TRANSFORMER
9EDT-101A
STEPDOWN TRANSFORMER
9EDT-111A
STEPDOWN TRANSFORMER
9EDT-201A
STEPDOWN TRANSFORMER
9EDT-211A

2/9
STATION CONTROLLER [ INDEXER UNIT ]
EEDC-0011
STATION CONTROLLER [ TRANSPORT UNIT ]
EERC-0011
STATION CONTROLLER [ SPIN UNIT ]
EESC-0011
STATION CONTROLLER [ BAKE UNIT ]
EEBC-0012
STATION CONTROLLER [ UEEW UNIT ]
EEEC-002
STATION CONTROLLER [ IF-B UNIT ]
EEEB-001
MAIN I/0 IFC BOX
EEMH-001
MAIN EXTERNAL IFC BOX
EEMI-001
STATION CONTROLLER
EEYC-0#11
MAIN PANEL [ STANDARD TYPE ]
EEMP-001#
MAIN PANEL [ MOTORED TYPE ]
EEMP-0112
INDEXER PANEL
EEDP-001
PORTABLE PANEL IFC BOX
EEMJ-002

D-SPIN 80B ELECTRICAL CIRCUIT DIAGRAM LIST
3/9
INDEXER A UNIT [ VACUUMLESS TYPE ]
EED#-001
INDEXER A UNIT [ VACUUM TYPE ]
EED#-0#1#
INTERFACE UNIT [ TYPE B ]
EEI#-####
TRANSPORT UNIT
EERM-OO1

4/9

SPIN UNIT [ COATER ]
EESM-€”0O1

SPIN UNIT [ POSITIVE DEVELOPER ]
EESM-O02

SPIN UNIT [ PIQ COATER ]
EESM-003

SPIN UNIT [ SCRUBBER ]
EESM-030

SPIN VACUUM SENSOR
EEFT-O01

SPIN CUP [ COATER, POSITIVE DEVELOPER ]
EESM~010

SPIN CUP [ MOTORED EBR NOZZLE ]
EES#-011

SPIN COVER
EESM-O20

RESIST PUMP CYLINDER SENSOR
EEFT-021

SPIN TWO-€”WAY WASTE DRAIN
EEFT-O51

D-SPIN 80B ELECTRICAL CIRCUIT DIAGRAM LIST
5/9

CHEMICAL FLOW/LEVEL SENSOR
E##-0#1

SPIN CHEMICAL IFC BOX
EEFH-001

SPIN IFC BOARD
EESD-O01

EXTERNAL ALARM IFC BOARD
EEKD-O01

CHEMICAL FLOW/LEVEL SENSOR IFC BOARD
EEFD-001

D-SONIC IFC BOX
EEFI-001

EXHAUST CONTROLLER
EESW-0#1

DRAIN BOX SENSOR
EEFT-O#11

AUTO-DRAIN BOX SENSOR
EEC#-0#1

DIRECT-€”DRAIN SENSOR
EEFT-O71

SV IFC BOARD
EECS-O#1
D-SPIN 80B ELECTRICAL CIRCUIT DIAGRAM LIST

6/9

BAKE UNIT [ HP(HH,AH) ]
EEBM-O##
BAKE UNIT [ CP(AC) ]
EEBN-O#1
BAKE UNIT [ LPAH ]
EEBO-0#1
BAKE SV
EEBS-010
BAKE IFC BOARD
EEBD-O01
HEATER CONTROLLER
EEB#-0O1##
COMMON T0 CHEMICAL CONTROLLER
EEC#-001
CHEMICAL CONTROLLER [ SD ONLY ]
EEC#-011
CHEMICAL CONTROLLER [ SC+SD TYPE ]
EEC#-001
SwITCHINC BOTTLES SENSOR
EECN-0#1
AUTO-SUPPLY SYSTEM SENSOR
EECN-0#11

7/9

LOWER LIMIT SENSOR
EEH#-0#1
EXHAUST SOURCE PRESSURE SENSOR
EEHW-€˜O#1
DIW SOURCE PRESSURE SENSOR [ SPIN UNIT ]
EEHW-011
SOURCE PRESSURE SENSOR
EE##”OO1
LEAKAGE SENSOR
EEHY-O11
CIRCUIT BREAKER BOX
EEPB-00#
AC POWER SUPPLY
EEP#-00#
MAIN POWER ON/OFF SWITCH BOX
EEMK-001
EMERGENCY POWER OFF SWITCH
EEPI-OO1

D-SPIN 80B ELECTRICAL CIRCUIT DIAGRAM LIST

8/9
TOWER-€”LAMP
EEMT-€”0O1

DEEW UNIT
EEUM-0O2

IMAGE SENSOR CONTROLLER
EEUE-001
DEEW POWER SUPPLY BOX
EEUB-001
HOST,AGV IFC BOX
EEMX-00#1

DRIVER UNIT POWER RELAY CABLE
EEKL-OO1

9/9
AIR CONDITIONING UNIT ALARM CABLE
EEHW-€”0#1

CABLE CONNECTION [ MAIN CONTROLLER ]
EEML-001

CABLE CONNECTION [ INDEXER UNIT ]
EEDL-O01

CABLE CONNECTION [ TRANSPORT UNIT ]
EERL-001

CABLE CONNECTION [ SPIN UNIT ]
EESL-O01

CABLE CONNECTION [ SPIN CHEMICAL IFC BOX ]
EEFL-OO1

CABLE CONNECTION [ BAKE UNIT ]
EEBLâ€-O01

CABLE CONNECTION [ CHEMICAL CONTROLLER ]
EECLâ€-O01

CABLE CONNECTION [ ALARM IFC BOX ]
EEHL-O01

CABLE CONNECTION [ INTERFACE UNIT (TYPE B) ]

CABLE CONNECTION [ UEEW UNIT ]
EEEL-0O1

CABLE CONNECTION [ DEEW UNIT ]
EEUL-O01